Self Resetting Overspeed Governor
Self Resetting Overspeed Governor
Self Resetting Overspeed Governor
Self Resetting Overspeed Governor
Self Resetting Overspeed Governor
Self Resetting Overspeed Governor
Self Resetting Overspeed Governor

Self Resetting Overspeed Governor

REQUEST QUOTE

Available in 100FPM, 150FPM, 200FPM, 250FPM, 350FPM and 500FPM.

All models come with a full guard as well as a CSA approved limit switch. The self-resetting overspeed governor has a live shaft option and a pull through of 1200lbs.

This governor has a remote trip and self-resetting function. It can be remotely reset, perfect for MRL (machine roomless) or basement traction installations or any limited access installation.

Description

  • Built to meet ASME A17.1 and EN81-1
  • CSA approved limit switch
  • Remote set and reset capabilities
  • Tested, preset and sealed at factory
  • Comes with overspeed switch
  • Comes with full rope guard
  • Comes with selenoid
  • Options (available at an additional charge):
    • Live shaft for encoder available
      (diameters: .25″ / .472″ / .75″ & 1″)
  • Sheave diameter: 305mm/12″
  • Rope type: 8 or 9.5mm 8 x S(19) / 3/8″ 
  • Max. pull through: up to 1200lbs
  • Min. pull through: 300lbs
  • Shipping weight: 35kg/77lbs

Delco Governors Product Line (PDF)

 

Self-Resetting Overspeed Governor Tripping Speed Chart

Running Speed Max Overspeed Switch Setting Max Tripping Speed Delco SKU
FPM M/S FPM M/S FPM M/S Order #
100 0.64 158 0.8 175 0.89 C-12-2100
150 0.76 189 0.96 210 1.06 C-12-2150
200 1.02 252 1.28 280 1.42 C-12-2200
250 1.27 303 1.54 337 1.71 C-12-2250
350 1.75 407 2.07 452 2.3 C-12-2350
500 2.54 563 2.86 625 3.18 C-12-2500